{"product_id":"sundance-jacuzzi-3pump-system-circuit-board-880-maxxus-aspen-permaclear-smart-logic-part-6600392","title":"Sundance® \/ Jacuzzi® 3‑Pump System Circuit Board – 880™ Maxxus \/ Aspen (PermaClear + Smart Logic) Part #6600‑392","description":"\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number: 6600-392\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand: Sundance Spas\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3‑Pump System Circuit Board – 880™ Maxxus \/ Aspen (PermaClear + Smart Logic)\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch4\u003e\u003cstrong\u003e⚠️ IMPORTANT DISCLAIMER – PLEASE READ BEFORE PURCHASING\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThere are \u003cem\u003eno refunds or returns\u003c\/em\u003e on electronic spa parts.\u003c\/li\u003e\n\u003cli\u003ePlease verify compatibility with your hot tub model before ordering.\u003c\/li\u003e\n\u003cli\u003eAll electronic components are covered under the original manufacturer’s warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003ePart \u003cstrong\u003e6600‑392\u003c\/strong\u003e is the OEM \u003cstrong\u003e3‑pump system circuit board\u003c\/strong\u003e used in Sundance® 880™ Series Maxxus and Aspen spas, as well as select Jacuzzi® Premium models. This board supports \u003cstrong\u003ePermaClear\u003c\/strong\u003e, \u003cstrong\u003eSmart Logic\u003c\/strong\u003e, \u003cstrong\u003eLCD control\u003c\/strong\u003e, and \u003cstrong\u003ecirculation pump management\u003c\/strong\u003e, and is designed for 3‑pump high‑output hydrotherapy systems.\u003c\/p\u003e\n\u003cp\u003eIt is the official factory replacement for earlier boards \u003cstrong\u003e6600‑155\u003c\/strong\u003e, \u003cstrong\u003e6600‑160\u003c\/strong\u003e, and \u003cstrong\u003e6600‑398\u003c\/strong\u003e, and includes updated firmware (EPROM Rev \u003cstrong\u003e3.1A+\u003c\/strong\u003e). \u003c\/p\u003e\n\u003cp\u003eThis board is \u003cstrong\u003enew OEM\u003c\/strong\u003e, never rebuilt or refurbished.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003eCompatible Spa Models \u0026amp; Years\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e✔ \u003cstrong\u003eSundance® 880™ Series\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMaxxus® \u0026amp; Aspen®\u003c\/strong\u003e across multiple generations:\u003c\/p\u003e\n\u003cdiv class=\"___i31lg00 f10pi13n f14t3ns0 f1nbblvp fat0sn4 f1ov4xf1 fekwl8i f1lmfglv f1oz7aqm f1abmfm4 f1w619qj f16h0jq8\"\u003e\n\u003ctable class=\"___1hm93bs f1ddd56o f16vktn6 f1enuhaj fdclmfp f1ev3kgc ftgm304 f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f1s2k7dp f8fmt76 fjvbh62 fysh76l fic4ptz f1yenhzu f1yn6nvh f14tj6oe f1jq587y f1el8yx3 f1pymoxg f1ofu761 fe6itr f7coize f1794535 f70r78m f4zgifc fk1v6el f16pyhcb fo436u6 fzy4j18 fc43013 f1hmrcvb fc4t9fq fgp09rh fjnyn6r\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eYear Range\u003c\/th\u003e\n\u003cth\u003eCompatible Models\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003cstrong\u003e2005 – Spring 2008\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eMaxxus\u003c\/td\u003e\n\u003ctd\u003eUses 6600‑155 originally (Rev 9.61A+) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003cstrong\u003eSpring 2008 – 2011\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eMaxxus\u003c\/td\u003e\n\u003ctd\u003eUses 6600‑160 originally (Rev 9.61B+) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003cstrong\u003e2012 – 2013\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eMaxxus, Aspen\u003c\/td\u003e\n\u003ctd\u003eAccepts 6600‑155 \/ 6600‑160 \/ 6600‑392 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003cstrong\u003e2014+\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eMaxxus, Aspen\u003c\/td\u003e\n\u003ctd\u003e3‑Pump NT systems with Smart Logic \u0026amp; PermaClear \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e✔ \u003cstrong\u003eJacuzzi® Premium (OEM Shared Platform)\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eJacuzzi® 3‑Pump LCD 60Hz systems (2014+)\u003c\/li\u003e\n\u003cli\u003eUsed interchangeably with Sundance® 6600‑392, 6600‑160, 6600‑155, 6600‑398\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Details\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoard Type:\u003c\/strong\u003e 3‑Pump main system circuit board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Features:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003ePermaClear® UV system\u003c\/li\u003e\n\u003cli\u003eCirculation pump logic\u003c\/li\u003e\n\u003cli\u003eSmart Logic timing\u003c\/li\u003e\n\u003cli\u003eLCD topside interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEPROM Version:\u003c\/strong\u003e Rev \u003cstrong\u003e3.1A+\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplaces:\u003c\/strong\u003e 6600‑155, 6600‑160, 6600‑398\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupports:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e3 jet pumps\u003c\/li\u003e\n\u003cli\u003eCirculation pump\u003c\/li\u003e\n\u003cli\u003eSmart heater logic\u003c\/li\u003e\n\u003cli\u003eUV counter\/indicator compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical:\u003c\/strong\u003e 60Hz configuration (jumper‑selectable Fahrenheit\/Celsius, 50Hz\/60Hz, LED\/Incandescent light logic) \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003ePurpose \u0026amp; Performance\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThis board controls the \u003cstrong\u003ecore spa functions\u003c\/strong\u003e in Sundance®\/Jacuzzi® 3‑pump luxury models:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJet pump sequencing\u003c\/li\u003e\n\u003cli\u003eWater temperature regulation\u003c\/li\u003e\n\u003cli\u003eHeater safety logic\u003c\/li\u003e\n\u003cli\u003ePermaClear UV operation\u003c\/li\u003e\n\u003cli\u003eSmart filtration cycles\u003c\/li\u003e\n\u003cli\u003eLighting system logic\u003c\/li\u003e\n\u003cli\u003eDiagnostic \u0026amp; trouble log capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eReplacing a failing PCB resolves issues such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePump not activating\u003c\/li\u003e\n\u003cli\u003eHeater not powering\u003c\/li\u003e\n\u003cli\u003eUV\/PermaClear errors\u003c\/li\u003e\n\u003cli\u003eFLO \/ OH \/ ILOC logic issues\u003c\/li\u003e\n\u003cli\u003eDead or unresponsive topside controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is the \u003cstrong\u003emain logic board\u003c\/strong\u003e for high‑end Sundance\/Jacuzzi systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003eRelated \/ Interchangeable Parts\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"___i31lg00 f10pi13n f14t3ns0 f1nbblvp fat0sn4 f1ov4xf1 fekwl8i f1lmfglv f1oz7aqm f1abmfm4 f1w619qj f16h0jq8\"\u003e\n\u003ctable class=\"___1hm93bs f1ddd56o f16vktn6 f1enuhaj fdclmfp f1ev3kgc ftgm304 f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f1s2k7dp f8fmt76 fjvbh62 fysh76l fic4ptz f1yenhzu f1yn6nvh f14tj6oe f1jq587y f1el8yx3 f1pymoxg f1ofu761 fe6itr f7coize f1794535 f70r78m f4zgifc fk1v6el f16pyhcb fo436u6 fzy4j18 fc43013 f1hmrcvb fc4t9fq fgp09rh fjnyn6r\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003cstrong\u003e6600‑155\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eEarlier Maxxus board (Rev 9.61A+) – replaced by 6600‑392\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003cstrong\u003e6600‑160\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eMaxxus board (Rev 9.61B+) – replaced by 6600‑392\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003cstrong\u003e6600‑398\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eAspen\/Maxxus NT board – replaced by 6600‑392\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003cstrong\u003e6000‑515\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eTransformer used with these boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003cstrong\u003e6600‑167 \/ 6600‑110\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eTemperature\/hi‑limit sensors compatible with 880 Series packs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003eOrdering Notes\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronics are final‑sale\u003c\/strong\u003e except for warranty replacement.\u003c\/li\u003e\n\u003cli\u003eBoard must match spa’s \u003cstrong\u003e3‑pump setup\u003c\/strong\u003e, \u003cstrong\u003eNT system\u003c\/strong\u003e, and \u003cstrong\u003ePermaClear\/UV\u003c\/strong\u003e configuration.\u003c\/li\u003e\n\u003cli\u003eJumper settings \u003cstrong\u003emust be configured after installation\u003c\/strong\u003e (60A\/50A logic, UV, temperature scale, pump count).\u003c\/li\u003e\n\u003cli\u003eEnsure the circulation pump runtime settings and Clearray\/UV options are correctly set after board installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen replacing older boards with a newer board always verify that the Clearray® setting is shut off (if applicable) and that the circulation pump run-time is set correctly.\u003cstrong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Sundance Spas","offers":[{"title":"Default Title","offer_id":46355768770732,"sku":"6600-392","price":1584.24,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/2077\/8156\/files\/6600-392.png?v=1786647659","url":"https:\/\/snowvalleyspas.ca\/products\/sundance-jacuzzi-3pump-system-circuit-board-880-maxxus-aspen-permaclear-smart-logic-part-6600392","provider":"Snow Valley Spas","version":"1.0","type":"link"}